AIR-OIL HEAT EXCHANGERS
IP55
230/400Volt
Elec.M.B 14

Vertical or horizontal mounting

Datos técnicos
ItemOil flowCapacityWeightVoltageFrequencyCurrent absorptionPotencia Ø FanAir flowNoise levelRpm
 [l/min][l][kg][V][Hz][A][W][mm][m3/h][dB(A)]
HY235.1-07A70-28020,2100230/40050/603,9800630525581920
Rendimiento
https://www.oesse.com/wp-content/uploads/2020/01/HY23507_rendimento.png[kW/K][l/min]
Caída de presión
https://www.oesse.com/wp-content/uploads/2020/01/HY23507_perdita.png[bar][l/min]

Oil T 80°C
T Amb. 40°C
1 kW = 860 Kcal/h – 1 HP = 0,75 kW

ISO VG 32 at 40°C
Viscosity - ISO VG 32 Oil
Oil22324668150
Correction factor0,811,21,63
Technical data are not binding - The graphs show the central range of heat exchange data
Accesorios

Mounting systems - from HY232 to HY235 - vertical

Mounting systems - from HY232 to HY235 - horizontal

Fixed temperature thermostats with threaded port 3/8"G

Fixed temperature thermostats with threaded port 1/2"G

Adjustable thermostat

Descargue el catálogo

Solicite el catálogo de nuestros nuevos intercambiadores electroventilados serie HY

 

 

Póngase en contacto con el equipo Oesse.